Overview
This Global Pharmaceutical company (GP)* is a leader in the discovery
and the advancement in the treatment of some of the most difficult to
treat diseases. GP employs more than 20,000 people globally, and
its products are sold in more than 100 countries.
* Due to confidentiality agreements, we are not able to provide the
client name. We will refer to the organization as GP throughout this
case study.
The Challenge
GP has set long term emissions reduction targets and expects to meet
the goals through short term and long term energy efficiency projects
and operational improvements. GP also expects to incorporate energy
efficient design into new buildings and renovations, and to implement
renewable energy projects.
GP's portfolio of buildings includes energy intensive research and development buildings, administrative offices, central plants, manufacturing, and distribution facilities across the globe.
GP's goals include efficiency and sustainability through a 20% reduction of CO2 emissions by 2020. To this end, GP was interested in implementing targeted energy conservation measures and technologies at one of its campuses.
Results achieved
* Energy savings financial summary
* Total energy savings: $233,000 (annual).
* Simple payback: 0.4 years.
* Net present value: $561,000
* Other operational benefits
* Improved sustainability and environmental stewardship.
Achieved 1,700+ metric tons in annual CO2 emissions reduction, which is
the equivalent of taking 358 cars off the road.
* Predictive maintenance: Initiated inspection and reprogramming of equipment prior to failure.
* Vendor management: Verified optimum sequence of
operations that were programmed into the building automation system
(BAS) by outsourced facilities management vendors, and maintained 24/7
operations.
Cimetrics' Solution
Cimetrics was selected to provide its Analytika Pro solution for 5
buildings comprising over 860,000 square feet including R&D and
office buildings. Cimetrics collaborated with Siemens, GP's
building automation system provider, to connect to and collect sensor
and actuator data from over 7,900 physical points. Data was collected
every 15 minutes, 24 hours a day, 365 days a year, totaling more than
750,000 data samples per day. The following systems were
monitored: 44 hot water and chilled water distribution pumps, 4
boilers, 8 heat exchangers, 51 fume hoods, 42 air handling units, 4
heat recovery units, over 500 terminal units and exhaust fans.
Over 1,000 Analytika software algorithms then analyzed the data to
identify opportunities to reduce energy consumption, improve comfort
and reduce operations and maintenance costs. Analytika also
uncovered potential equipment problems, and provided opportunities for
profitable retrofit projects.
Experienced Cimetrics engineers leveraged Analytika software to
identify opportunities, determine root cause, and calculate annual
savings impact. Actionable recommendations were documented and provided
to the client both through online and offline channels. Cimetrics' role
did not end with providing recommendations; Cimetrics engineers engaged
with the client team on a regular basis to help answer questions,
coordinate implementation, and provide regular feedback on progress.
Example of fault detection and diagnostics:
Heat Recovery Performance Verification
Four (4) large air handling units (AHUs) in one of the buildings have
heat recovery; however, only two (2) were operating efficiently.
The heat recovery system supplies a 50% glycol solution to the four (4) heat recovery coils in AHU-1A, AHU-1B, AHU-1C, and AHU-1D. The system utilizes a single 100 HP constant flow pump which operates when the outside air temperature decreases below 54°F and is disabled when the outside air temperature rises above 55°F. The exhaust side of the heat recovery system is comprised of nine (9) coils located in the fume exhaust system.
The heat recovery was operating as follows:
AHU-1A: There was less heat recovery occurring. The heat recovery return water temperature was higher than in AHU-1B and AHU-1C.
AHU-1B: The heat recovery system was operating efficiently.
AHU-1C: The heat recovery system was operating efficiently.
AHU-1D: There was less heat recovery occurring. The heat recovery
return water temperature was higher than in AHU-1A, AHU-1B, and AHU-1C.
This issue was not detected on-site because there was partial heat
recovery occurring from the exhaust side. In addition, the AHUs
were able to maintain discharge temperature utilizing the preheat coils
so there were no low temperature alarms.
[an error occurred while processing this directive]However, the issue was identified with
Analytika. The root cause of the fault was that the heat recovery
valves were not opening completely and the water was bypassing the
coils.
Solution
Cimetrics worked with GP staff and their controls vendor to fix the
valves that were not opening completely, and to maximize heat recovery
for all four (4) AHUs.
Annual energy savings achieved: $34,852 (annual)
Annual carbon emissions reduction: 605 metric tons