EMAIL INTERVIEW Samuel Smith & Ken Sinclair

Dr. Samuel Smith, President of Adept Systems

Samuel M. Smith, Ph. D. Is the President and founder of Adept Systems Inc. (ASI). Adept is a technology manufacturing, research and development company focused on networked intelligent automation systems.  ASI is based in Eagle Mountain Utah. Adept specializes in standards based automation technology including but not limited to LonTalk and IP. ASI has a product line of smart LonTalk over IP routers, gateways, and nodes. ASI has also conducted DoD sponsored research in survivable automation systems. Dr. Smith received a Ph.D. in Electrical and Computer Engineering from Brigham Young University (BYU) in 1991.


New LonTalk over IP router

It's not just the least expensive but also the smallest (only uses 35 mm of Din rail) LON over IP router on the market.

Articles
Interviews
Releases
New Products
Reviews
Forums
Sponsors
Archives
Past Issues
AutomatedBuildings.com

ABB

Sinclair: You have just released a new LonTalk over IP router, the GRouter4. What does this new product bring to the table that isn't already provided by other similar products on the market?

Smith:  As you know we have been making LON over IP routers for some time, We have used that experience to push the envelope of performance for price. We believe that one of the ways to grow the LON market in general is to lower the cost of LON network infra-structure without sacrificing performance. The GRouter4 Lon over IP router does just that, and then some. It's not just the least expensive but also the smallest (only uses 35 mm of Din rail) LON over IP router on the market. It is standards compliant and highly interoperable. It's the only one with a WiFi interface option. The goal is to help systems integrators be more competitive, not only in the LON market, but also make LON more competitive vis a vis other automation protocols. There is a perception that IP is not a first class citizen with LON. This is not true. The open standard 852 protocol is a fully standard channel for LonTalk. Using 852, you could build an IP only LonTalk network if you wanted to.

Sinclair: How does it help with competitiveness?

Smith:  One of the headaches a system integrator faces is being able to optimize the use of resources for a particular application. In this case network bandwidth and wiring. Using LON over IP for the network backbone has significant advantages. Typically IP infrastructure (wiring, switches) already exists so it's a great place to leverage capability for little cost. Even when IP infrastructure does not exist, the huge IP market keeps costs down. Typically the single biggest cost in using an IP backbone is the LON interface to IP. By driving this cost down we change the value equation.

There are two aspects of systems design that one needs to have flexibility in order to optimize. One of these is granularity, that is, being able to allocate resources in right sized chunks. If the chunks are too big, it usually means waste. And typically there is a minimum cost per chunk no matter how small. The other is scalability, that is, being able to grow the capacity of the network conveniently.

Sinclair: Can you give an example, to illustrate the point?

Smith:  Sure, until now the high cost of LON over IP routers has resulted in many LON installations using a two tier approach to a LON backbone. The control points typically use an FTT-10 channel. The first tier of the backbone is a slightly higher speed TP-1250 channel. For this you need an FT-10 to 1250 router for each FT-10 channel. Each 1250 network is then routed on the second tier to an IP/ Ethernet backbone. Recently, quad-port FT-10 to 1250 routers have become available that lower the cost per port somewhat. The problem is that a single 1250 channel can not handle 4 fully loaded FT-10 channels and the Lon over IP routers may not have the capacity to handle 4 fully loaded FT-10 channels. So you have a mismatch. You may have to put fewer nodes on each FT-10 channel or break your LON network up into more channels. If you need to add just one more channel you have a big cost to add another set of routers. The metric one should use here is bit per second per dollar. Or if normalized to standard SNVT sized packets, packets per second per 1000 dollars (pps/ k). So using 600 packets per second for a loaded 1250 channel and retail pricing for a LON/IP router plus four port FT-10 router gets you about 480 pps/k.

In contrast, you can get four GR4s for a little more than the cost of one 4 port FT-10 to 1250 router plus one LON/IP router from one of our competitors, and all four use less than half the space. This means you can put four fully loaded FT-10 channels directly onto a 100 Base-T ethernet backbone. But a loaded FT-10 channel is 200 pps, or 800 pps for four. So the metric including the extra cost is a little better at 530 pps/k. If you need a little more capacity you can add it one GR4 at a time, no mismatch. This comparison is the best case for the two tier model. If you go to a three or two port switch or need 5 ports your pps/k is much lower than the comparable one tier GR4 based design, so you get better granularity and scalability with the GR4.

Sinclair: What about installations where back bone bandwidth is not the main problem, but remote connectivity is?

Smith:  Historically, remote connectively has been the big application for LON/over IP routing. We support that as a standards compliant 852 LON over IP router. However, as a result of customer requests we have added some unique features to our routers to help in this area. One feature is what we call transparent flood mode. Two of our routers can be configured to bridge FT-10 channels over an IP channel. The FT-10 channels don't even have to know that there is an IP link between them. This really helps in some legacy installations where the master controller's network management does not have the smarts to configure routers. And of course our WiFi version makes it possible to bridge between buildings wirelessly for those application where even IP wiring is not available.

Reliable Controls Sinclair: Couldn't I just put another main controller in the remote building. Many of the head end controllers have their own IP based communication protocol that allows for multi-building connectively?

Smith:  Yes you could, but it may not be the most cost effective solution. Two of our GR4 routers will typically cost a lot less than another head end controller. Especially if all you are doing is connecting to a handful of nodes at a remote site. If you have multiple remote sites the economics get even better, as you only need one GR4 at the location of the head end controller and only one additional per remote site. Also your integration is simpler; you are just bridging the networks at the LON level, plus you have a transparent, flat, and open network.

Sinclair: What about remote connectivity applications where high speed Internet is not available like low bandwidth IP networks that use cell phones, GPRS?

Smith:  That's a good question, One of the optional features of the 852 protocol is that it tries to simplify the IP management using a configuration server. Unfortunately, the initial formation of an 852 channel can generate a big burst of IP traffic while the devices and configuration server share routing information. This can be a problem for a low bandwidth GRPS based IP channel. Fortunately, we, have several solutions for this. We uniquely support the optional 852 manual mode configuration, which does not require a configuration server. Manual mode allows you to customize your configuration. If all the remote traffic is to the head end and back, then by appropriate manual mode specification of each device's channel list, we can minimize configuration traffic. We also recently added a serial transaction mode that gets rid of bursts in configuration traffic or limits them to a selectable level. Finally, we have an 852 to 852 routing option. When this option is enabled, a GR4 can route between two different 852 channels. This enables one to isolate the devices on the low speed GRPS IP channel from say a network management tool and other devices on a high speed Ethernet IP channel. These unique features of the GR4 make is a great choice for this application. They also provide what I have been talking about, granularity, and scalability.

Sinclair: What if you need to go long distances wirelessly, can the GR4 do that?

Smith:  The GR4 uses a standards compliant 802.11b WiFi transceiver with an RP-SMA antenna connector. With WiFi, range is a function of the environment and your antenna/amplifier configuration. While a pair of 2 dbi whip antennas may only get you 100 meters, a pair of 15 dbi directional antennas can go multiple kilometers. The RP-SMA antenna connector allows you to use a wide variety of antenna and amplifier configurations to get whatever range (within reason) that you need. There is so much inexpensive 802.11b WiFi equipment on the market to enable wireless applications. We focus on providing the critical LON to WiFi interface in a compact, relatively inexpensive package, so that system integrators can leverage WiFi for their needs.

Sinclair: Seems like a lot for such a little device.

Smith:  It is, and we say its about time. In higher volumes the GR4 is very economical. We want to expand the LON marketplace by making LON relatively less expensive to install thereby making our customers more competitive not only with respect to other LON integrators but relative to other protocols as well.